T-Stor
 

T-Stor >
Irish Journal of Agricultural & Food Research >
IJAFR, volume 43, 2004 >

Please use this identifier to cite or link to this item: http://hdl.handle.net/11019/555

Title: Effects of the design of a milking unit on vacuum variations during simulated milking
Authors: O'Callaghan, Edmund, J.
Keywords: Milking machine
Simulation
Vacuum
Issue Date: 2004
Publisher: Teagasc (Agriculture and Food Development Authority), Ireland
Citation: E.J. O’Callaghan. Effects of the design of a milking unit on vacuum variations during simulated milking. Irish Journal of Agricultural and Food Research 43: 237–245, 2004.
Series/Report no.: Irish Journal of Agricultural and Food Research;43
Abstract: The vacuum variations at the apex of an artificial teat during simulated milking were measured in a factorial-design laboratory test involving six cluster types, two internal diameters (13.5 mm and 16 mm) of long milk tube (LMT), three water flow rates (4, 6 and 8 l/min), simultaneous (4 × 0) and alternate (2 × 2) pulsation patterns and three pulsator ratios (60, 64, and 68%). Four of the six clusters were fitted with wide-bore tapered liners and represented all combinations of two claw volumes (150 or 420 ml) and two short-milk-tube bores (8.5 mm and 13.5 mm). Two clusters were fitted with narrow-bore liners (22 and 25 mm) that had large-bore short milk tubes and large claw volumes. The vacuum variations were expressed as mean vacuum at the teat-end during the b-phase of pulsation (TVB), mean vacuum at the teat end measured over complete pulsation cycles (TV), minimum vacuum measured over complete pulsation cycles (TVM) and amplitude of vacuum fluctuation measured over complete pulsation cycles (TVF). The highest level of TVB was recorded with wide-bore tapered liners. For a milking unit fitted with a wide-bore tapered liner TVF was reduced and TVM increased by increasing either the bore of the short milk tube or the volume of the claw. When the bore of the LMT was increased TVB, TV and TVF increased. Simultaneous pulsation gave higher TVB (P < 0.001) and higher TVF (P < 0.001) than alternate pulsation for all cluster types. The overall effects of altering pulsator ratio were significant but small in practical terms. There were significant interactions between cluster type and water flow rate and pulsation pattern for TVB, TV, TVM and TVF.
Description: peer-reviewed
URI: http://hdl.handle.net/11019/555
http://www.teagasc.ie/research/journalarchives/vol43no22004fullpdfs.asp
ISSN: 0791-6833
Appears in Collections:IJAFR, volume 43, 2004

Files in This Item:

File Description SizeFormat
03.03.Effects.of.the.pdf276.35 kBAdobe PDFView/Open

This item is protected by original copyright


View Statistics

Items in T-Stor are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! Teagasc - The Agriculture and Food Development Authority  2012  - Feedback