T-Stor
 

T-Stor >
Irish Journal of Agricultural & Food Research >
IJAFR, Volume 50, no. 2, 2011 >

Please use this identifier to cite or link to this item: http://hdl.handle.net/11019/68

Title: Analysis and evaluation of the teat-end vacuum condition in different automatic milking systems
Authors: Ströbel, U.
Rose-Meierhöfer, S.
Öz, H.
Entorf, A.C.
Popp, L.
Brunsch, R.
Keywords: Fluctuation
Phase
Quarter individual
Reduction
Wet-test-method
Issue Date: 2011
Publisher: Teagasc (Agriculture and Food Development Authority), Ireland
Citation: Analysis and evaluation of the teat-end vacuum condition in different automatic milking systems. U. Ströbel, S. Rose-Meierhöfer, H. Öz, A.C. Entorf, L. Popp and R. Brunsch. IJAFR Vol. 50, No. 2 (2011), pp. 209-221
Series/Report no.: Irish Journal of Agricultural and Food Research;Volume 50: Number 2, 2011
Abstract: The number of automatic milking systems (AMSs) installed worldwide shows an increasing trend. In comparison to the preliminary models, new versions employ more sophisticated sensor technology than ever before. The originally developed AMSs were characterised by larger vacuum fluctuations and vacuum reductions than conventional milking systems. The objective of this study was to find out whether this situation still holds or if an improvement has occurred. The vacuum behaviour at the teat end of an artificial teat during simulated milking was measured in a study that involved different AMS types (AMS A, B and C). Each system was tested over a range of flow rates (0.8 to 8.0 L/min). The wet-test method was used and teat-end vacuum behaviour was recorded. At a flow rate of 4.8 L/min, the lowest vacuum fluctuation (6.4 kPa in b-phase) was recorded for AMS A, while the lowest vacuum reduction (3.5 kPa in the b-phase) was obtained for AMS B. AMS C yielded higher values for vacuum reduction and vacuum fluctuation. Consequently, it was concluded that AMS A and B, in terms of construction and operational setting (vacuum level), are more appropriate than AMS C. Nevertheless, high values for vacuum reduction or fluctuation have a negative effect on the teat tissue. Hence, one of the future challenges in milk science is to develop a control system that is able to allow fine adjustments to the vacuum curve at the teat end.
Description: peer-reviewed
URI: http://hdl.handle.net/11019/68
ISSN: 0791-6833
Appears in Collections:IJAFR, Volume 50, no. 2, 2011

Files in This Item:

File Description SizeFormat
Vol. 50 No. 2 pp 209-221.pdf392.48 kBAdobe PDFView/Open

This item is protected by original copyright


View Statistics

Items in T-Stor are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! Teagasc - The Agriculture and Food Development Authority  2012  - Feedback