Loading...
Evaluation of a fluorescence and infrared backscatter sensor to monitor acid induced coagulation of skim milk
Panikuttira, Bhavya ; Payne, Frederick A. ; O'Shea, Norah ; Tobin, John ; O'Donnell, Colm P.
Panikuttira, Bhavya
Payne, Frederick A.
O'Shea, Norah
Tobin, John
O'Donnell, Colm P.
Citations
Altmetric:
Date
2019-05-03
Collections
Files
Loading...
main article
Adobe PDF, 2.45 MB
Research Projects
Organizational Units
Journal Issue
Citation
Panikuttira B, Payne FA, O'Shea N, Tobin JT, O'Donnell CP. Evaluation of a fluorescence and infrared backscatter sensor to monitor acid induced coagulation of skim milk. Innovative Food Science & Emerging Technologies 2019;54:219-224; doi https://doi.org/10.1016/j.ifset.2019.04.011.
Abstract
A prototype sensor that employs both ultraviolet excited fluorescence and infrared light backscatter was evaluated as an in-line process analytical technology (PAT) tool to monitor acid induced coagulation kinetics of skim milk. Coagulation experiments were carried out at 32 °C using three concentrations of glucono-delta-lactone (GDL). Measurement of storage modulus (G′) of acidified skim milk gel was used as a reference rheological method to monitor the coagulation kinetics. Prediction models were developed to predict the times required for acidified skim milk coagulum to reach selected G′ values (0.5 Pa, 1 Pa, 5 Pa, 10 Pa and 15 Pa) using time parameters extracted from the ultraviolet excited fluorescence and infrared light backscatter profiles. A strong correlation was observed between the predicted times developed using time parameters extracted from the prototype sensor profiles and the measured G′ times extracted from the rheometer (R2 = 0.97, standard error of prediction = 2.8 min). This study concluded that the prototype fluorescence and infrared backscatter sensor investigated combined with the developed rheological prediction model can be used as a potential PAT tool for in-line monitoring of coagulation kinetics in the manufacture of acid induced milk gels.
Industrial relevance:
The prototype fluorescence and infrared backscatter sensor investigated in this study combined with the developed rheological prediction model can be employed to monitor and control coagulation kinetics in a wide range of dairy processing applications including fresh cheese varieties and yoghurt manufacture.