Evaluation of a fluorescence and infrared backscatter sensor to monitor acid induced coagulation of skim milk
dc.contributor.author | Panikuttira, Bhavya | |
dc.contributor.author | Payne, Frederick A. | |
dc.contributor.author | O'Shea, Norah | |
dc.contributor.author | Tobin, John | |
dc.contributor.author | O'Donnell, Colm P. | |
dc.date.accessioned | 2019-10-14T15:51:53Z | |
dc.date.available | 2019-10-14T15:51:53Z | |
dc.date.issued | 2019-05-03 | |
dc.identifier.citation | Panikuttira B, Payne FA, O'Shea N, Tobin JT, O'Donnell CP. Evaluation of a fluorescence and infrared backscatter sensor to monitor acid induced coagulation of skim milk. Innovative Food Science & Emerging Technologies 2019;54:219-224; doi https://doi.org/10.1016/j.ifset.2019.04.011. | en_US |
dc.identifier.uri | http://hdl.handle.net/11019/1796 | |
dc.description | peer-reviewed | en_US |
dc.description.abstract | A prototype sensor that employs both ultraviolet excited fluorescence and infrared light backscatter was evaluated as an in-line process analytical technology (PAT) tool to monitor acid induced coagulation kinetics of skim milk. Coagulation experiments were carried out at 32 °C using three concentrations of glucono-delta-lactone (GDL). Measurement of storage modulus (G′) of acidified skim milk gel was used as a reference rheological method to monitor the coagulation kinetics. Prediction models were developed to predict the times required for acidified skim milk coagulum to reach selected G′ values (0.5 Pa, 1 Pa, 5 Pa, 10 Pa and 15 Pa) using time parameters extracted from the ultraviolet excited fluorescence and infrared light backscatter profiles. A strong correlation was observed between the predicted times developed using time parameters extracted from the prototype sensor profiles and the measured G′ times extracted from the rheometer (R2 = 0.97, standard error of prediction = 2.8 min). This study concluded that the prototype fluorescence and infrared backscatter sensor investigated combined with the developed rheological prediction model can be used as a potential PAT tool for in-line monitoring of coagulation kinetics in the manufacture of acid induced milk gels. Industrial relevance: The prototype fluorescence and infrared backscatter sensor investigated in this study combined with the developed rheological prediction model can be employed to monitor and control coagulation kinetics in a wide range of dairy processing applications including fresh cheese varieties and yoghurt manufacture. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Elsevier | en_US |
dc.relation.ispartofseries | Innovative Food Science & Emerging Technologies;Vol. 54 | |
dc.rights | Attribution-NonCommercial-ShareAlike 3.0 United States | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-sa/3.0/us/ | * |
dc.subject | skim milk | en_US |
dc.subject | induced coagulation | en_US |
dc.subject | Rheological properties | en_US |
dc.subject | cutting times | en_US |
dc.subject | gels | en_US |
dc.subject | Acidification | en_US |
dc.subject | Temperature | en_US |
dc.subject | Fermentation | en_US |
dc.subject | Gelation | en_US |
dc.subject | fluorescence and infrared backscatter sensor | en_US |
dc.title | Evaluation of a fluorescence and infrared backscatter sensor to monitor acid induced coagulation of skim milk | en_US |
dc.type | Article | en_US |
dc.embargo.terms | 2020-05-03 | en_US |
dc.identifier.doi | https://doi.org/10.1016/j.ifset.2019.04.011 | |
dc.contributor.sponsor | Dairy Processing Technology Centre | en_US |
dc.contributor.sponsorGrantNumber | TC/2014/0016 | en_US |