• Accuracy of predicting milk yield from alternative milk recording schemes

      Berry, Donagh; Olori, V. E.; Cromie, A. R.; Veerkamp, Roel F.; Rath, Myles V; Dillon, Pat; Teagasc Walsh Fellowship Programme (Cambridge University Press, 2005-02)
      The effect of reducing the frequency of official milk recording and the number of recorded samples per test-day on the accuracy of predicting daily yield and cumulative 305-day yield was investigated. A control data set consisting of 58 210 primiparous cows with milk test-day records every 4 weeks was used to investigate the influence of reduced milk recording frequencies. The accuracy of prediction of daily yield with one milk sample per test-day was investigated using 41 874 testday records from 683 cows. Results show that five or more test-day records taken at 8-weekly intervals (A8) predicted 305-day yield with a high level of accuracy. Correlations between 305-day yield predicted from 4-weekly recording intervals (A4) and from 8-weekly intervals were 0.99, 0.98 and 0.98 for milk, fat and protein, respectively. The mean error in estimating 305-day yield from the A8 scheme was 6.8 kg (s.d. 191 kg) for milk yield, 0.3 kg (s.d. 10 kg) for fat yield, and −0.3 kg (s.d. 7 kg) for protein yield, compared with the A4 scheme. Milk yield and composition taken during either morning (AM) or evening (PM) milking predicted 24-h yield with a high degree of accuracy. Alternating between AM and PM sampling every 4 weeks predicted 305-day yield with a higher degree of accuracy than either all AM or all PM sampling. Alternate AM-PM recording every 4 weeks and AM + PM recording every 8 weeks produced very similar accuracies in predicting 305-day yield compared with the official AM + PM recording every 4 weeks.
    • Effect of liner design, pulsator setting, and vacuum level on bovine teat tissue changes and milking characteristics as measured by ultrasonography

      Gleeson, David E; O'Callaghan, Edmond J; Rath, Myles V (Biomed Central, 2004-05-01)
      Friesian-type dairy cows were milked with different machine settings to determine the effect of these settings on teat tissue reaction and on milking characteristics. Three teat-cup liner designs were used with varying upper barrel dimensions (wide-bore WB = 31.6 mm; narrow-bore NB = 21.0 mm; narrow-bore NB1 = 25.0 mm). These liners were tested with alternate and simultaneous pulsation patterns, pulsator ratios (60:40 and 67:33) and three system vacuum levels (40, 44 and 50 kPa). Teat tissue was measured using ultrasonography, before milking and directly after milking. The measurements recorded were teat canal length (TCL), teat diameter (TD), cistern diameter (CD) and teat wall thickness (TWT). Teat tissue changes were similar with a system vacuum level of either 50 kPa (mid-level) or 40 kPa (low-level). Widening the liner upper barrel bore dimension from 21.0 mm (P < 0.01) or 25.0 mm (P < 0.001) to 31.6 mm increased the magnitude of changes in TD and TWT after machine milking. Milk yield per cow was significantly (P < 0.05) higher and cluster-on time was reduced (P < 0.01) with the WB cluster as compared to the NB1 cluster. Minimum changes in teat tissue parameters were achieved with system vacuum level of 40 kPa and 50 kPa using NB and WB clusters, respectively. Similar changes in teat tissue and milk yield per cow were observed with alternate and simultaneous pulsation patterns. Widening pulsator ratio from 60:40 to 67:33 did not have negative effects on changes in teat tissue and had a positive effect on milk yield and milking time. Milk liner design had a bigger effect on teat tissue changes and milking characteristics than pulsation settings.