Show simple item record

dc.contributor.authorRayburn, Maire C.
dc.contributor.authorChigerwe, Munashe
dc.contributor.authorBarry, John
dc.contributor.authorKennedy, Emer
dc.date.accessioned2023-11-09T15:57:59Z
dc.date.available2023-11-09T15:57:59Z
dc.date.issued2019-08-31
dc.identifier.citationMaire C. Rayburn, Munashe Chigerwe, John Barry, Emer Kennedy, Short communication: Use of a digital refractometer in assessing immunoglobulin G concentrations in colostrum and the first 5 transition milkings in an Irish dairy herd, Journal of Dairy Science, Volume 102, Issue 8, 2019, Pages 7459-7463, ISSN 0022-0302, https://doi.org/10.3168/jds.2019-16467.en_US
dc.identifier.urihttp://hdl.handle.net/11019/3393
dc.descriptionpeer-revieweden_US
dc.description.abstractTransition milk is a source of immunoglobulin G (IgG) and could potentially be used to provide calves with passive immunity, when the IgG concentration is ≥50 g/L. Assessment of IgG concentrations in transition milk would be required before feeding and could be conducted using cow-side tests such as refractometers. Currently, limited information is available on the ability of refractometers to assess transition milk quality. We hypothesized that digital refractometry could be used to provide an accurate cow-side assessment of IgG concentrations in colostrum and transition milk, and IgG concentration in colostrum and one or more transition milking in an Irish herd is >50 g/L. The objectives of this study were to determine the IgG concentrations in colostrum and first, second, third, fourth, and fifth transition milk, and determine the utility of a digital refractometer in assessing quality of colostrum and transition milk produced by cows in a pasture-based dairy production system. A convenient sample of 75 dairy cows were enrolled. Colostrum and transition milk IgG concentrations were determined by radial immunodiffusion and refractometry. Sensitivity and specificity of the refractometer were determined and cut-off points that maximized sensitivity and specificity were determined using receiver operating characteristic curves. Median (range) IgG concentrations in colostrum and first, second, third, fourth, and fifth milking were 99.6, 43.5, 12.5, 5.3, 1.9, and 1.8 g/L, respectively. The sensitivity (0.8–1) of digital refractometry in identifying samples with low IgG concentrations in colostrum, first, second, and third transition milk was acceptable. In contrast, digital refractometry was not useful for assessing IgG concentrations in the fourth and fifth milking due to low IgG concentrations.en_US
dc.language.isoenen_US
dc.publisherElsevieren_US
dc.relation.ispartofseriesJournal of Dairy Science;Vol 102
dc.rights© 2019 American Dairy Science Association®.
dc.rightsAttribution-NonCommercial-ShareAlike 4.0 International*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0/*
dc.subjectdairy cowen_US
dc.subjecttransitionen_US
dc.subjectimmunoglobulinen_US
dc.subjectrefractometeren_US
dc.subjectmilken_US
dc.titleShort communication: Use of a digital refractometer in assessing immunoglobulin G concentrations in colostrum and the first 5 transition milkings in an Irish dairy herden_US
dc.typeArticleen_US
dc.identifier.doihttps://doi.org/10.3168/jds.2019-16467
dc.contributor.sponsorUniversity of California–Davis Global Programs Seed Grantsen_US
dc.source.volume102
dc.source.issue8
dc.source.beginpage7459
dc.source.endpage7463
refterms.dateFOA2023-11-09T15:58:00Z
dc.source.journaltitleJournal of Dairy Science


Files in this item

Thumbnail
Name:
1-s2.0-S0022030219305314-main.pdf
Size:
179.7Kb
Format:
PDF
Description:
main article

This item appears in the following Collection(s)

Show simple item record

© 2019 American Dairy Science Association®.
Except where otherwise noted, this item's license is described as © 2019 American Dairy Science Association®.