Effect of mechanical premilking stimulation on milking duration in late lactation
Name:
Effect-of-mechanical-premilkin ...
Size:
419.9Kb
Format:
PDF
Description:
main article
Citation
J. Upton, M. Browne, P. Silva Bolona, Effect of mechanical premilking stimulation on milking duration in late lactation, Journal of Dairy Science, 2022, , ISSN 0022-0302, https://doi.org/10.3168/jds.2022-22453.Abstract
This study documents the effect of mechanical prestimulation on the milking duration of pasture-based cows in late lactation to better harness increased capacity of automation in the milk harvesting process. Premilking stimulation, provided via manual or mechanical means, has been shown to promote the milk letdown reflex and assist in achieving quick, comfortable, and complete milk removal from the udder. The literature is lacking knowledge on the effect of mechanical premilking stimulation on milking duration, especially in late lactation and in pasture-based systems, and many pasture-based farms do not practice a full premilking routine because of a lack of labor availability. The current study addresses this gap in knowledge. In this study, we tested 2 treatments: (1) the No Stim treatment used normal farm milking settings with no premilking preparation and (2) the Stim treatment used 60 s of mechanical premilking stimulation, with a rate of 120 cycles per minute and a pulsator ratio of 30:70 on cluster attachment. Once the 60 s of stimulation had elapsed, normal milking settings resumed for the remainder of the milking. Sixty cows were enrolled in the study, which ran for 20 d. The effect of treatment on a.m. milking duration was significant, a.m. milking duration for Stim was 12 s shorter than that of No Stim. The effect of treatment on p.m. milk duration was not significant. Treatment had no effect on a.m./p.m. milk yields, average milk flowrates or peak milk flowrates. Significant differences emerged between treatments on a.m. and p.m. dead time (time from cluster attachment to reach a milk flowrate of 0.2 kg/min). The a.m. and p.m. dead times were 6 s shorter for Stim compared with No Stim. The time taken to achieve peak milk flowrate (time to peak) at morning milking was 7 s shorter for Stim compared with No Stim, and treatment yielded no significant effects on time to peak at p.m. milkings. Treatment also had no significant effect on log10 somatic cell count. Although the percentage of congested teat-ends and teat-barrels was numerically lower for Stim versus No Stim, no statistical differences were detected across these measures. Based on the results of the study, we found merit in applying 60 s of mechanical pre-stimulation at a.m. milking from a milking duration perspective. However, the strategy was not as successful for the p.m. milking. Analysis of the milk flowrate profiles recorded during the study suggest potential utility in employing different machine settings for various milkings based on anticipated yield and level of udder fill.Funder
Science Foundation Ireland (SFI); Department of Agriculture, Food and Marine; Dairymaster, Causeway, IrelandGrant Number
16/RC/3835ae974a485f413a2113503eed53cd6c53
https://doi.org/10.3168/jds.2022-22453
Scopus Count
Collections
The following license files are associated with this item:
- Creative Commons