Show simple item record

dc.contributor.authorKennedy, Deirdre
dc.contributor.authorWilkinson, Martin G.
dc.date.accessioned2024-02-29T13:47:47Z
dc.date.available2024-02-29T13:47:47Z
dc.date.issued2015
dc.identifier.citationKennedy, D. and Wilkinson, M.G. (2015) “Application of flow cytometry to the detection of pathogenic bacteria,” Flow Cytometry in Microbiology: Technology and Applications, pp. 91–108. Available at: https://doi.org/10.21775/9781910190111.05.en_US
dc.identifier.urihttp://hdl.handle.net/11019/3684
dc.descriptionpeer-revieweden_US
dc.description.abstractOutbreaks of infections have emphasized the necessity for rapid and economic detection methods for pathogens in samples ranging from those of clinical origin to food products during production and retail storage, and increasingly, in environmental samples. Flow cytometry (FCM) allows the rapid acquisition of multi-parametric data regarding cell populations within fluidised samples. However, the application of FCM to pathogen detection depends on the availability of specific fluorescent probes such as antibodies and RNA probes capable of detecting and isolating pathogens from these diverse samples. A particular issue for FCM methodology is the ability to recover and discriminate bacteria from the sample matrix which may pose a major technical hurdle towards accurate and sensitive analysis. This review article focuses on detection of pathogens using FCM in samples originating from food, water, environmental and clinical sources and outlines the current state of the art and potential future applications.en_US
dc.language.isoenen_US
dc.publisherCaister Academic Pressen_US
dc.relation.ispartofseriesFlow Cytometry in Microbiology: Technology and Applications;Vol 23
dc.rightsAttribution-NonCommercial-ShareAlike 4.0 International*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0/*
dc.subjectPathogenic bacteriaen_US
dc.titleApplication of Flow Cytometry to the Detection of Pathogenic Bacteriaen_US
dc.typeArticleen_US
dc.identifier.doihttps://doi.org/10.21775/9781910190111.05
dc.source.booktitleFlow Cytometry in Microbiology: Technology and Applications
dc.source.beginpage91
dc.source.endpage108
refterms.dateFOA2024-02-29T13:47:49Z


Files in this item

Thumbnail
Name:
cimb-23-00003.pdf
Size:
475.0Kb
Format:
PDF
Description:
main article

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-ShareAlike 4.0 International
Except where otherwise noted, this item's license is described as Attribution-NonCommercial-ShareAlike 4.0 International